BLOG

What is Instant Start (IS)

Horace He

Last Updated: December 26, 2023

What is Instant Start (IS)

Instant Start (IS) is a starting method used for fluorescent lamps. It involves the use of electronic ballasts that apply a high voltage directly to the lamp’s electrodes without preheating the cathode. This immediate application of voltage allows the lamp to ignite instantly, hence the name “Instant Start.”

Maybe You Are Interested In

  • Load Current: 10A Max
  • Auto/Sleep Mode
  • Time delay: 90s, 5min, 10min, 30min, 60min
  • Load Current: 10A Max
  • Auto/Sleep Mode
  • Time delay: 90s, 5min, 10min, 30min, 60min
  • Load Current: 10A Max
  • Auto/Sleep Mode
  • Time delay: 90s, 5min, 10min, 30min, 60min
  • Load Current: 10A Max
  • Auto/Sleep Mode
  • Time delay: 90s, 5min, 10min, 30min, 60min
  • Load Current: 10A Max
  • Auto/Sleep Mode
  • Time delay: 90s, 5min, 10min, 30min, 60min
  • Load Current: 10A Max
  • Auto/Sleep Mode
  • Time delay: 90s, 5min, 10min, 30min, 60min
  • Occupancy mode
  • 100V ~ 265V, 5A
  • Neutral Wire Required
  • 1600 sq ft
  • Voltage: DC 12v/24v
  • Mode: Auto/ON/OFF
  • Time Delay: 15s~900s
  • Dimming: 20%~100%
  • Occupancy, Vacancy, ON/OFF mode
  • 100~265V, 5A
  • Neutral Wire Required
  • Fits the UK Square backbox
  • Voltage: DC 12V
  • Length: 2.5M/6M
  • Color Temperature: Warm/Cold White
  • Voltage: DC 12V
  • Length: 2.5M/6M
  • Color Temperature: Warm/Cool White
  • Voltage: DC 12V
  • Length: 2.5M/6M
  • Color Temperature: Warm/Cool White
  • Voltage: DC 12V
  • Length: 2.5M/6M
  • Color Temperature: Warm/Cold White
rz036 occupancy sensor switch ceiling mounted
  • Occupancy mode
  • 12V ~ 24V, 5A
  • Neutral Wire Required
  • 1600 sq ft
  • Voltage: DC 12v/24v
  • Day/Night Mode
  • Time delay: 15min, 30min, 1h(default), 2h
  • Occupancy, Vacancy, ON/OFF mode
  • 120V 5A
  • Neutral Wire Required
  • Fits the US 1-Gang wall box
  • Occupancy, Vacancy, ON/OFF mode
  • 120V, 5A
  • Neutral Wire Required
  • Fits the US 1-Gang wall box
  • Occupancy, Vacancy, ON/OFF mode
  • 100~265V, 5A
  • Neutral Wire Required
  • Fits the European round backbox
rz021 us occupancy vacancy sensor switch front
  • Occupancy, Vacancy, ON/OFF mode
  • 120Vac, 5A
  • Requires Hot wire, Load wire
  • No Neutral/Ground Wire Required
  • Fits the US 1-Gang wall box
rz023 uk occupancy vacancy sensor switch front
  • Occupancy, Vacancy, ON/OFF mode
  • 100~265V, 5A
  • No Neutral/Ground Wire Required
  • Fits the UK square pattress box

One of the key advantages of instant start ballasts is their energy efficiency. Compared to other ballast types, such as rapid start ballasts, Instant Start ballasts consume 1.5 to 2 watts less per lamp. This energy-saving feature makes them a preferred choice for various lighting applications. Another benefit of instant start ballasts is their parallel lamp circuitry. This means that if one lamp fails, the others on the circuit remain lit. This feature ensures uninterrupted lighting and prevents damage to the ballast or the remaining lamps. Instant start ballasts also offer longer remote wiring distance, making them suitable for installations where the ballast is located far away from the lamps. This flexibility in design and installation allows for more versatile lighting setups.

In terms of installation, instant start ballasts are known for their simplicity. They have less complicated wiring requirements, making the installation process easier and more efficient. Additionally, instant start ballasts have the capability to start lamps at lower temperatures. While other ballast types may require a minimum temperature of 50 degrees Fahrenheit, they can start lamps even at 0 degrees Fahrenheit. This makes them ideal for applications in cold environments where low-temperature starting is necessary.

Looking For Motion-Activated Energy-Saving Solutions?

Contact us for complete PIR motion sensors, motion-activated energy-saving products, motion sensor switches, and Occupancy/Vacancy commercial solutions.

Frequently Asked Questions

What Happens if You Don’t Use a Ballast

Without a ballast, a lamp or bulb will experience a significant increase in its current draw, leading to uncontrollable behavior. The absence of a ballast prevents the power from stabilizing, which can be problematic when these lamps are connected to high power sources. However, with a ballast in place, the energy is regulated, preventing any sudden rise in current.

Should I Replace Ballast or Buy New Fixture

For improved energy efficiency, reliability, and durability, it is recommended to replace the ballasts rather than purchasing new fixtures. Older ballasts not only have energy efficiency concerns but also lack the reflective geometry that newer options provide.

What Happens if You Put LED Bulbs in a Fluorescent Fixture

In summary, the answer is affirmative. The installation of linear LED tube bulbs in a fluorescent fixture is a straightforward process. All you need to do is remove the existing fluorescent bulb and replace it with the LED light. Further details are provided below to assist you in making an informed decision to switch from linear fluorescent light bulbs to tube LEDs.

What Is One Disadvantage of a Fluorescent Light Is That It Requires a Ballast

Disadvantages of fluorescent lights include the need for a separate ballast to operate, which not only consumes energy but can also be expensive to replace. Additionally, the wattage of fluorescent lights is limited by the existing ballast installed in the fixture, making it costly to switch to higher or lower output bulbs.

Are T8 and T12 Ballast Interchangeable

Waveform Lighting’s T8 LED tube lights are compatible with various ballast configurations, including ballast, ballast bypass single ended, and ballast bypass double ended. Therefore, they can be safely utilized in T12 fixtures as long as the T12 ballast is bypassed or removed.

Can I Put a T8 Ballast in a T12 Fixture

The primary distinction between T8 and T12 tubes lies in their diameter. T12 tubes have a diameter of 1.5 inches, whereas T8 tubes are only one inch in diameter. However, when it comes to socket sizes, lengths, and the distance between pins, both types are identical. Therefore, it is safe to say that T8 LED tubes can be installed in a T12 fixture without any issues or concerns.

Is It Worth Replacing Fluorescent Tubes With LED

Compared to fluorescent tubes, LED lights offer a significant advantage in terms of efficiency. LED lights are able to convert 95% of their energy into light, resulting in up to 80% more efficiency compared to fluorescent bulbs. Additionally, LED lights provide a strong and consistent output at a lower wattage, making them a worthwhile replacement for fluorescent tubes.

Will LED Bulbs Work if Ballast Is Bad

Yes, LED lamps can still function even if the ballast is faulty, as long as they are equipped with an internal driver that is capable of operating without the need for a functioning ballast. For instance, Philips has developed a tube that is specifically designed to be compatible with an existing electronic ballast, allowing for a seamless plug-and-play experience.

Leave a Comment

English